Journal of Laboratory Medicine and Quality Assurance ; : 239-246, 2009.
Article in Korean | WPRIM | ID: wpr-228389

ABSTRACT

BACKGROUND: Hemoglobin A1c (HbA1c) is a good marker for the monitoring of glycemic control in patients with diabetes mellitus and various methods are used for determination of HbA1c. We evaluated the analytical performance of ion-exchange high-performance liquid chromatography system, standard mode (G8 SM) and variant mode (G8 VM) of Tosoh HLC-723 G8 (Tosoh Corporation, Japan) and Cobas Integra 800 (Roche Diagnostics, Germany) using new reagent (Tina-quant Hemoglobin A1c Gen.2, Roche Diagnostics) for immunoassay. METHODS: G8 SM, G8 VM, and Cobas Integra 800 were evaluated for linearity, precision, comparison of method, and speed. Variant II Turbo (Bio-Rad Laboratories, USA) was used for comparison test for above three analyzers. RESULTS: Three instruments showed within-run precision (CVs) of 0.52-1.12% in low level and 0.39-0.90% in high level control material. Total run precision (CVs) were in 0.95-1.26% in low level and 0.60-0.94% in high level control material. The linearity was good for the range of 4-15% and comparison with Variant II turbo was excellent with 0.9878-0.9977 of correlation coefficient. Analytical speed was 2 min/1 min in G8 SM, 3.5 min/1.5 min in G8 VM, and 14.7 min/18 sec in Cobas Integra 800, respectively. CONCLUSIONS: HLC-723 G8 SM and VM, and Cobas Integra 800 were showed excellent linearity, precision, and comparison with other instrument. We should consider the characteristics including analytical method and speed in each instrument when clinical laboratory is planning to introduce different equipment for HbA1c determination.


Subject(s)
Humans , Chromatography, High Pressure Liquid , Chromatography, Liquid , Diabetes Mellitus , Hemoglobins , Immunoassay
2.
Journal of Laboratory Medicine and Quality Assurance ; : 273-277, 2008.
Article in Korean | WPRIM | ID: wpr-42693

ABSTRACT

BACKGROUND: We evaluated overall performance and analysis time of newly developed HLC-723 G8 (Tosoh corp., Tokyo, Japan) HbA1c autoanalyzerwhich utilizes cation-exchange HPLC method. METHODS: Linearity, precision, correlation with Variant II Turbo (Bio-Rad Laboratories, Hercules, CA, USA), analysis time, labile HbA1c (L-A1c) separation ability and stability of refrigerated sample at 4degrees C were evaluated. RESULTS: HLC-723 G8 showed good linearity between HbA1c 4.9-12.0% range (R2=0.9995). Within-run and total imprecision (CVs) were less than 1.0%. Correlation with Variant II Turbo and L-A1c separation ability were excellent. Analysis time per sample took 1.0 min. Stability of refrigerated sample at 4degrees C for at least 21 days was good. CONCLUSIONS: HLC-723 G8 showed good analytical performance and its rapid analysis time enables us to support outpatient diagnosis of diabetic patients efficiently.


Subject(s)
Humans , Chromatography, High Pressure Liquid , Outpatients , Tokyo